VM operation such as screen resolution, shutdown fails.

Following events can be seen.

set console window screen resolution. A general system error occurred : invalid fault.

Following lines can be seen in vmware.log

2019-05-14T15:49:35.058Z| mks| I125: MKSControlMgr: New VNC connection 0
2019-05-14T15:49:35.123Z| mks| I125: VNCENCODE 352 VNCEncodeChooseRegionEncoder: region encoder adaptive. Resolution: 1600 x 647
2019-05-14T15:49:35.505Z| vmx| I125: Tools_SetGuestResolution: Sending rpcMsg = Resolution_Set 1366 492
2019-05-14T15:49:45.161Z| vmx| I125: GuestRpcSendTimedOut: message to toolbox timed out.
2019-05-14T15:50:05.164Z| vmx| I125: GuestRpcSendTimedOut: message to toolbox timed out.

This issue happens when vmware tools on guest OS unable to communicate with host that can be fix by reinstalling latest version of VMware tools on guest OS.